Skip to main content

Renewable Power & Industrial Solar EPC · SREDA Certified Net Metering

Commercial & Industrial Rooftop Solar PV Systems

Reduce factory electricity expenses by up to 40%, ensure LEED compliance, and export surplus energy through SREDA Net Metering with Pacific Powertech's turnkey solar engineering.

Industrial rooftop solar PV panel installation by Pacific Powertech
Clean Power Generation

Turnkey C&I Solar PV • Grid Synchronized EPC

Up to 40% Energy Cost Savings Drastically curb daytime peak grid tariff expenses
100 kW – 5 MW+ EPC Project Scale Engineered for factory sheds, RCC roofs & commercial complexes
SREDA Approved Net Metering EPC Full clearance with DESCO, DPDC, BREB, BPDB, and NESCO
25 Years Module Performance Tier-1 Monocrystalline Bifacial and TOPCon technology
Renewable Engineering Architecture

Industrial Solar Engineering & Integration Solutions

We combine Tier-1 photovoltaic technology with heavy-duty electrical substation engineering to deliver robust, high-yield clean energy systems.

Commercial & Industrial (C&I) Rooftop Solar PV
Pacific Powertech Field Engineering
Rooftop Solar EPC

Commercial & Industrial (C&I) Rooftop Solar PV

High-yield photovoltaic systems engineered for industrial standing-seam metal sheds, corrugated roofs, and RCC flat rooftops with zero penetrations and aerodynamic wind clamping.

Tier-1 Bifacial & TOPCon Monocrystalline PV modules
Wind tunnel certified anodized aluminum and HDG mounting structures
Zero-roof-leakage engineered seam clamps and integrated maintenance walkways
Levelized Cost of Electricity (LCOE) substantially lower than utility grid tariffs
Solar Inverter Substations & Grid Interconnection
Pacific Powertech Field Engineering
Substation Engineering

Solar Inverter Substations & Grid Interconnection

Unlike equipment traders, Pacific Powertech designs and manufactures the complete step-up transformer, LT/HT switchgear, and protection array needed to connect your solar generation directly to factory buses and the national grid.

Low-loss solar step-up distribution transformers (0.4 kV to 11 kV / 33 kV)
Custom LT AC Combiner panels with microprocessor air circuit breakers
Class 0.2S high-precision bi-directional net-metering energy meters
Integrated surge protection (SPD Type 1+2) and lightning arresters
Hybrid Solar-Diesel & Smart Energy Management
Pacific Powertech Field Engineering
Microgrid Control

Hybrid Solar-Diesel & Smart Energy Management

Intelligent reverse-power protection and fuel-saver controllers that enable rooftop solar plants to operate harmoniously alongside standby Perkins, Cummins, and Caterpillar diesel generators during outages without reverse-power tripping.

Zero-export and reverse-power relay protection preventing generator damage
Automated solar-generator fuel-saver controllers for up to 60% diesel savings
Dynamic plant controller adjusting inverter active power in milliseconds
Battery Energy Storage System (BESS) integration readiness
SREDA Net Metering & Utility Liaison
Pacific Powertech Field Engineering
Turnkey Regulatory Clearance

SREDA Net Metering & Utility Liaison

Complete regulatory management from initial technical feasibility and structural vetting to utility sanction, bi-directional net-metering synchronization, and final commissioning certificate issuance.

Official utility sanction processing (DPDC, DESCO, BREB, BPDB, NESCO)
Comprehensive CAD Single Line Diagrams (SLD), layout schematics, and simulation reports
Utility-grade bi-directional net-meter testing and calibration oversight
Government Electrical Licensing Authority safety audit compliance
Pedigree • Quality Assurance

The Pacific Powertech Solar Advantage

Why Bangladesh's leading manufacturing facilities trust our power engineering pedigree for rooftop solar installations.

In-House Substation Manufacturing

We manufacture custom transformers, LT/HT switchgear, and PFI plants in-house, ensuring absolute electrical compatibility and eliminating third-party markups.

Tier-1 Certified Hardware Only

We install only BloombergNEF Tier-1 solar modules (Longi, Jinko, Trina) and tier-one string inverters (Huawei, Sungrow) backed by comprehensive 25-year performance warranties.

Cloud SCADA & Real-Time Telemetry

Continuous string-level monitoring, inverter efficiency analytics, environmental sensor tracking (irradiance, ambient temperature), and instant automated breakdown alerts.

24/7 Operations & Maintenance (O&M)

Preventive module cleaning protocols, scheduled thermographic drone inspections to detect micro-cracks or hotspots, and rapid on-call engineering field dispatch.

Lifecycle Delivery

Turnkey EPC Project Delivery Methodology

From initial rooftop drone survey to grid-connected commissioning, our structured engineering process ensures maximum solar yield and safety.

01

Site Survey & 3D Shadow Analysis

Comprehensive drone LIDAR survey, structural capacity auditing of roof purlins and trusses, and 3D irradiance modeling using PVsyst simulation software.

02

Electrical & Substation Engineering

String sizing, DC cable route optimization, inverter placement, transformer capacity verification, and protection coordination design.

03

Utility Approvals & Net Metering Sanction

Preparing and presenting technical dossiers to SREDA and the respective utility distributor for net metering sanction approval.

04

Equipment Procurement & In-House Fabrication

Importing Tier-1 solar panels and inverters; fabrication of custom AC distribution boards, step-up transformers, and mounting hardware.

05

Mechanical Mounting & DC/AC Cabling

Precision installation using non-penetrating seam clamps, walkways, specialized double-insulated solar cables, and low-impedance earthing networks.

06

Testing, Commissioning & SCADA Integration

String open-circuit voltage testing, insulation resistance checks, bi-directional meter synchronization, and online SCADA dashboard handover.

Project Showcase • Actual Installations

Field Installations & Solar Project Gallery

Real-world rooftop solar photovoltaic arrays, inverter installations, and electrical balance-of-plant infrastructure engineered by Pacific Powertech.

Industrial Rooftop Solar PV System
C&I Rooftop Array

Industrial Rooftop Solar PV System

High-Efficiency Monocrystalline Module Field
Photovoltaic Installation

High-Efficiency Monocrystalline Module Field

Factory Shed Multi-Bay Solar Array
Industrial Power

Factory Shed Multi-Bay Solar Array

Rooftop Solar Array & Walkway Layout
Structural Architecture

Rooftop Solar Array & Walkway Layout

On-Grid Inverter Bank & Containment Lineup
Inverter Station

On-Grid Inverter Bank & Containment Lineup

Non-Penetrating Clamping & Cable Management
Mounting & Safety

Non-Penetrating Clamping & Cable Management

Solar Module Stringing & Earthing Grid
Electrical Balance of Plant

Solar Module Stringing & Earthing Grid

Industrial Shed Clean Energy Generation
Renewable Generation

Industrial Shed Clean Energy Generation

Technical Knowledge Base

Frequently Asked Questions on Industrial Solar

How does Net Metering work for industrial consumers in Bangladesh?

Under SREDA Net Metering guidelines, industrial consumers can install solar PV systems up to 70% of their sanctioned load (or up to 3 MW). Solar energy generated during daylight hours is consumed on-site first. Any surplus generation is automatically exported to the national utility grid (DESCO, DPDC, BREB, etc.) through a bi-directional meter and credited against your monthly electricity billing.

What is the typical financial payback period for an industrial solar PV system?

Given commercial and industrial electricity tariff rates in Bangladesh, most industrial rooftop solar installations achieve full capital payback within 3.5 to 4.5 years. With module performance warranties extending to 25 years, the remaining 20+ years deliver virtually free electricity.

Will the solar PV system function during grid power cuts or load shedding?

Standard on-grid inverters shut down during grid outages for safety (anti-islanding protection). However, Pacific Powertech engineers hybrid solar-diesel synchronization systems that enable the solar PV array to safely feed power alongside your backup diesel generators, cutting daytime diesel fuel expenditure by 40% to 60% without backfeeding into generators.

What rooftop structural considerations are necessary before installation?

Modern solar panels with aluminum mounting structures add approximately 12 to 15 kg per square meter of dead load. Before any installation, Pacific Powertech's structural engineers inspect roof trusses, purlins, and sheet gauge to guarantee compliance with the Bangladesh National Building Code (BNBC) and high wind load tolerances.

Turnkey Solar Engineering

Request a Complimentary Solar Feasibility Study

Speak directly with our renewable energy engineering desk to evaluate your roof capacity, simulate solar generation yields, and calculate your projected financial payback.

Engineering Publication • 20-Page Comprehensive Edition

Download the Complete Pacific Powertech Technical Catalog

Access complete engineering schematics, power transformer loss tables, switchgear dimensions, and automation panel specifications in our official 20-page reference catalog.

Technology & Component Brands

Current industrial brands specified across power distribution, switchgear and automation systems.